Hamamatsu L6305 L2D2 Deuterium Lamp

The Hamamatsu L6305 L2D2 Deuterium Lamp has a UV Glass window material with a guatanteed lifetime of 2000 hours. It is also known as L6305. The L2D2 Deuterium Lamps are specifically developed for analytical instruments. These L2D2 lamps offer excellent features essential for light sources in analytical instruments such as long service life, high stability and high output.

Applications

  • High Performance Liquid Chromatography,
  • UV-VIS  Spectrophotometer,
  • Thin Layer Chromatography,
  • Atomic Absorption Spectrophotometer,
  • Film Thickness Gauge etc.

Features

  • dimensional outline: “w” ,
  • Spectral distribution : 185 nm to 400 nm,
  • Aperture diameter : 0.5 mm,
  • Guaranteed life : 2000 h,
  • High stability, 
    • Fluctuation 0.005 % (p-p) Typ. (Equivalent to 2 x10-5 A.U.)
    • Drift +/-0.3 %/h

stability-l6301.jpg

  • Small intensity variation,

 intensity-variation-l6301.jpg

  • Less movement of arc emission point.

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 3.0 +/- 0.3 V dc, V ac
Filament Warm-up Current Typ. 5 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 0 to 1 V dc
Filament Operating Current Typ. 0 to 1.8 A dc

 

SKU: HAM L6305 Categories: , Tag:

Description

The Hamamatsu L6305 L2D2 Deuterium Lamp has a UV Glass window material with a guatanteed lifetime of 2000 hours. It is also known as L6305. The L2D2 Deuterium Lamps are specifically developed for analytical instruments. These L2D2 lamps offer excellent features essential for light sources in analytical instruments such as long service life, high stability and high output.

Applications

  • High Performance Liquid Chromatography,
  • UV-VIS  Spectrophotometer,
  • Thin Layer Chromatography,
  • Atomic Absorption Spectrophotometer,
  • Film Thickness Gauge etc.

Features

  • dimensional outline: “w” ,
  • Spectral distribution : 185 nm to 400 nm,
  • Aperture diameter : 0.5 mm,
  • Guaranteed life : 2000 h,
  • High stability, 
    • Fluctuation 0.005 % (p-p) Typ. (Equivalent to 2 x10-5 A.U.)
    • Drift +/-0.3 %/h

stability-l6301.jpg

  • Small intensity variation,

 intensity-variation-l6301.jpg

  • Less movement of arc emission point.

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 3.0 +/- 0.3 V dc, V ac
Filament Warm-up Current Typ. 5 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 0 to 1 V dc
Filament Operating Current Typ. 0 to 1.8 A dc

 

Additional information

Weight 0.25 lbs
Dimensions 4 × 6 × 4 in